VUTG
Rectifying unit of traction generator for AC-DC locomotives power supply.
Technical data:
The maximum amplitude of the generator linear electromotive force, 900 V
Input voltage frequency, 33...116 Hz
Rated output DC voltage, 810 V
Number of output channels of rectifying unit/all channels can be connected in parallel/ 6
Rated output voltage for one channel, А 900
Rated output voltage for six channels, А 5400
Category temperature range:
· ambient temperature, С -50...+60
· cooling-air temperature, С -40...+40
Rectifier’s efficiency with minimum rated current 99%
Minimum control of the rectifier 99%
Overall dimensions of controlled rectifier's case (length x depth x height), mm 850х350х1100
Overall dimensions of control unit case (length x depth x height), mm 850х350х600
Minimum weight of controlled rectifier's case, kg 350
Minimum weight of control unit case, kg 100
Note:
Rectifying unit consists of two cases of controlled rectifiers and control unit case.
All cases of rectifying unit have one way service.
Control unit case is set on the one of the cases of controlled rectifiers.
Rectifying unit RITG-5400/810-U2 have overall dimensions, that are 1,5 times less of the similar rectifying unit M-TPP-3000-U2, produced by OJSC «Electrovipryamitel», Saransk for PJSC “Kolomensky Zavod”.
Performance test of the controlled rectifier assembled with the control unit case of the rectifying unit for traction generator type VUTG-5400/810-U2 at “Electrtotyazhmash” Plant.
Large case (on the right) – of the controlled rectifiers.
Grey part (on the left) – control unit (microintegrated system, including power supply unit).
Electrical machine on the right – set with traction and auxiliary generator.
Case of the controlled rectifier without front end cover.