SPCH-21-U1
Static inverter SPCH-21-U1
Static inverter for electrical equipment package for carriages with an independent electrical supply and air conditioning SPCH-21-U1. The static inverter was tested by the Ministry of Railways of the Russian Federation.
Static inverter appearance
The inverter is designed to control the air-conditioning system of luxury carriages, the power supply of the air-conditioning system electric motors, such as: compressor electric motors, supply fans and condenser fans.
Advantages:
- Improved comfort level of passenger carriages.
- Accuracy and stability of output parameters.
- Solid-state reliability, greater service life of electrical equipment and machinery of air-conditioning systems.
- Facilitate the operating modes of air-conditioning system.
- Increase in service life of storage batteries.
- High rate of plates and units unification, supplied as plug-in package, providing ease of maintenance (with the possibility of a quick replacement in case of failure).
- Construction, that doesn’t require maintenance during operation.
- Plug(-to-plug) compatibility with existing wagon arrangement.
- Can be installed in the depot.
Static inverter SPCH-21-U1 provide:
• Reliable power supply for compressor electric motors, supply fan and condenser fan of air-conditioning system.
• Smooth and stepless variation of compressor discharge (by controlling the rotational speed of the compressor motor).
• Automatic soft start of electric motors.
• Receiving instructions and issuing signalling information for the wagon control system.
• Full-service diagnosis of electric motors and machineries of air-conditioning system and prevention of emergency situations.
Performance specification:
-
Power, kV 3…15
-
Rated input DC voltage, V 110
-
Input voltage spread, V 85…145
-
Number of phases of output voltage 1, 3
-
Rated output voltage, V 220, 380 ±10%
-
Rated frequency of output voltage, Hz 50
-
Sinusoidal output voltage
-
Rated output current, А, 8÷40
-
Maximum output current, А, minimum (during 1 min) 12÷60
-
Forced air ventilation
-
Category temperature range, ºС -40…+40
-
Mechanical hazards fitting according to GOST 17516-90 М25
-
Enclosure IP00
Protection:
-
Disconnection of channels at current 1,5 Iн.
-
Short circuit protection in power section.
-
Overvoltage protection.
-
Undervoltage protection.
-
Disconnection of channels at current unbalance of every channel
-
Inverter more than 20% of the rated value;
-
Disconnection of channels at coolant temperature more than 85±1 °С.
Reliability
The design, materials, technology, workmanship and control provide:
• Average error-free running time with confidence probability 0,9 (in km of car-mileage) – 600000 km.
• Average service life considering the use of spare tools and accessories kit – 28 years.
• Average inverter recovery time by means of single set of spare tools and accessories – minimum 30 mins.